64

CoolSmart TV (Optional) - Installation Overview

The CoolSmart system is designed to redirect the convective heat of the fireplaces from the front of the unit, just
above the glass, to a location higher on the wall. The use of this kit allows for reduced clearances to televisions
and a recessed cavity above the fireplace. When using this kit, disregard the standard framing dimensions and
follow the framing instructions for the CoolSmart kit.
When used on the PB72, this kit allows for the non-combustible facing height to be reduced. See illustration
below for details.
Ceiling
Max. 120"
(3048mm)
Min. 66-1/2"
(1690mm)
© Travis Industries
Installation
Min. 1-1/2" (39mm)
Min. 1-1/4"
(32mm)
Television
Min.
Min. 39"
10-3/8"
991mm
264mm
Min. 36"
915mm
28-5/8"
728mm
(for qualified installers only)
Max. 4-1/4" (108mm)
Optional Recessed Pocket
(Min. 39" 991mm above base of fireplace,
13-3/8" 340mm above top of screen trim)
Combustible Facing
(Min. 28-5/8" 728mm
above base of fireplace)
Non-Combustible
Facing Only
Top of Screen Trim
ProBuilder
(25-5/8" 651mm above
base of fireplace)
Linear
Fireplace
4/21/20 - 1458
PB 72 MV/GSB2/GSR2 Install