Intel® Light Guided Diagnostics
Intel® Server System SC5650HCBRP TPS
10. Intel
Light Guided Diagnostics
®
®
The Server Board in the Intel
Server System SC5650HCBRP has several onboard diagnostic
LEDs to assist in troubleshooting board-level issues. This section provides a description of the
location and function of each LED on the server boards.

10.1 5-volt Stand-by LED

Several server management features of these server boards require a 5-V stand-by voltage
supplied from the power supply. The features and components that require this voltage must be
present when the system is "power-down" include the Integrated BMC, onboard NICs, and
®
®
optional Intel
RMM3 installed in the Intel
RMM3 slot.
®
The LED is located near the Intel
SAS Entry RAID Module AXX4SASMOD slot in the lower-left
corner of the server boards and is labeled "5VSB_LED". It is illuminated when AC power is
applied to the platform and 5-V stand-by voltage is supplied to the server board by the power