Table 19. Performance Criteria - Intel SC5650HCBRP Product Specification

Hide thumbs Also See for SC5650HCBRP:
Table of Contents

Advertisement

Power Sub-system
Level
Description
A
The apparatus should continue to operate as intended. No degradation of performance.
B
The apparatus should continue to operate as intended. No degradation of performance
beyond spec limits.
C
Temporary loss of function is allowed provided the function is self-recoverable or
restorable by the operation of the controls.
4.1.2.7.1
Electrostatic Discharge Susceptibility
The power supply complies with the limits defined in EN 55024: 1998 using the IEC 61000-4-
2:1995 test standard and performance criteria B defined in Annex B of CISPR 24.
4.1.2.7.2
Fast Transient/Burst
The power supply complies with the limits defined in EN55024: 1998 using the IEC 61000-4-
4:1995 test standard and performance criteria B defined in Annex B of CISPR 24.
4.1.2.7.3
Radiated Immunity
The power supply complies with the limits defined in EN55024: 1998 using the IEC 61000-4-
3:1995 test standard and performance criteria A defined in Annex B of CISPR 24.
4.1.2.7.4
Surge Immunity
The power supply was tested with the system for immunity to AC Ringwave and AC
Unidirectional wave, both up to 2kV, per EN 55024:1998, EN 61000-4-5:1995 and ANSI C62.45:
1992.
The pass criteria included: No unsafe operation allowed under any condition; all power supply
output voltage levels remain within proper spec levels; no change in operating state or loss of
data during and after the test profile; no component damage under any condition.
The power supply complies with the limits defined in EN55024: 1998 using the IEC 61000-4-
5:1995 test standard and performance criteria B defined in Annex B of CISPR 24.
4.1.2.8
AC Line Dropout / Holdup
The following are the AC dropout requirements.
60

Table 19. Performance Criteria

Intel order number E81443-002
Intel® Server System SC5650HCBRP TPS