Table 115. Ssi 4-Pin Fan Header Pin-Out (J7K1, J9A2, J9A3); Table 116. Ssi 6-Pin Fan Header Pin-Out (J1K1, J1K2, J1K4, J1K5) - Intel SC5650HCBRP Product Specification

Hide thumbs Also See for SC5650HCBRP:
Table of Contents

Advertisement

Intel® Server System SC5650HCBRP TPS

Table 115. SSI 4-pin Fan Header Pin-out (J7K1, J9A2, J9A3)

Pin
Signal Name
1
Ground
2
12V
3
Fan Tach
4
Fan PWM

Table 116. SSI 6-pin Fan Header Pin-out (J1K1, J1K2, J1K4, J1K5)

Pin
Signal Name
1
Ground
2
12V
3
Fan Tach
4
Fan PWM
5
Fan Presence
6
Fan Fault LED
®
Note: Intel
Corporation server boards support peripheral components and can contain a
number of high-density VLSI and power delivery components that need adequate airflow to cool.
Intel's own chassis are designed and tested to meet the intended thermal requirements of these
components when the fully integrated system is used together. It is the responsibility of the
system integrator that chooses not to use Intel
vendor datasheets and operating parameters to determine the amount of airflow required for
their specific application and environmental conditions. Intel Corporation cannot be held
responsible if components fail or the server board does not operate correctly when used outside
any of its published operating or non-operating limits.
Revision 1.2
Type
GND
Ground is the power supply ground
Power
Power supply 12 V
In
FAN_TACH signal is connected to the BMC to monitor the fan speed
Out
FAN_PWM signal to control fan speed
Type
GND
Ground is the power supply ground
Power
Power supply 12 V
In
FAN_TACH signal is connected to the BMC to monitor the fan speed
Out
FAN_PWM signal to control fan speed
In
Indicates the fan is present
Out
Lights the fan fault LED