Table 17. Ac Line Sag Transient Performance; Table 18. Ac Line Surge Transient Performance - Intel SC5650HCBRP Product Specification

Hide thumbs Also See for SC5650HCBRP:
Table of Contents

Advertisement

Intel® Server System SC5650HCBRP TPS
Duration
Sag
Continuous
10%
0 to 1 AC
100%
cycle
> 1 AC cycle
>10%
Duration
Surge
Continuous
10%
0 to ½ AC
30%
cycle
4.1.2.5
AC Line Fuse
The power supply has a single line fuse on the Line (Hot) wire of the AC input. The line fusing is
acceptable for all safety agency requirements. The input fuse is a slow blow type. AC inrush
current will not cause the AC line fuse to blow under any conditions. All protection circuits in the
power supply will not cause the AC fuse to blow unless a component in the power supply failed.
This includes DC output load short conditions.
4.1.2.6
AC In-rush
AC line in-rush current does not exceed 55A peak for up to one-quarter of the AC cycle, after
which the input current is no more than the specified maximum input current. The peak in-rush
current is less than the ratings of its critical components (including input fuse, bulk rectifiers, and
surge limiting device).
The power supply meets the in-rush requirements for any rated AC voltage, during turn on at
any phase of AC voltage, during a single cycle AC dropout condition, as well as upon recovery
after AC dropout of any duration, and over the specified temperature range (T
4.1.2.7
Susceptibility Requirements
The power supply meets the following electrical immunity requirements when connected to a
cage with an external EMI filter that meets the criteria defined in the SSI document EPS Power
Supply Specification. For further information on Intel standards, please request a copy of the
Intel Environmental Standards Handbook.
Revision 1.2

Table 17. AC Line Sag Transient Performance

Operating AC
Line
Voltage
Frequency
Nominal AC
50/60 Hz
Voltage ranges
Nominal AC
50/60 Hz
Voltage ranges
Nominal AC
50/60 Hz
Voltage ranges

Table 18. AC Line Surge Transient Performance

Operating AC Voltage
Nominal AC Voltages
Mid-point of nominal AC
Voltages
Intel order number E81443-002
Loading
Performance Criteria
No loss of function or performance.
100%
No loss of function or performance.
75%
Loss of function acceptable, self
100%
recoverable.
Line Frequency
Performance Criteria
50/60 Hz
No loss of function or performance.
No loss of function or performance.
50/60 Hz
Power Sub-system
).
op
59

Advertisement

Table of Contents
loading

Table of Contents