Table 2. Mixed Processor Configurations - Intel SC5650HCBRP Product Specification

Hide thumbs Also See for SC5650HCBRP:
Table of Contents

Advertisement

Functional Architecture
Error
Processor family not
identical
Processor stepping
mismatch
Processor cache not
identical
Processor frequency
(speed) not identical
Processor Intel®
QuickPath
Interconnect speeds
not identical
26

Table 2. Mixed Processor Configurations

Severity
Halt
The BIOS detects the error condition and responds as follows:
Logs the error into the system event log (SEL).
Alerts the Integrated BMC about the configuration error.
Does not disable the processor.
Displays "0194: Processor 0x family mismatch detected" message in
the Error Manager.
Halts the system and will not boot until the fault condition is remedied.
Pause
The BIOS detects the stepping difference and responds as follows:
Checks to see whether the steppings are compatible – typically +/-
one stepping.
If so, no error is generated (this is not an error condition).
Continues to boot the system successfully.
Otherwise, this is a stepping mismatch error, and the BIOS responds as
follows:
Displays "0193: Processor 0x stepping mismatch" message in the
Error Manager and logs it into the SEL.
Takes Minor Error action and continues to boot the system.
Halt
The BIOS detects the error condition and responds as follows:
Logs the error into the SEL.
Alerts the Integrated BMC about the configuration error.
Does not disable the processor.
Displays "0192: Processor 0x cache size mismatch detected"
message in the Error Manager.
Halts the system and will not boot until the fault condition is remedied.
Halt
The BIOS detects the error condition and responds as follows:
Adjusts all processor frequencies to the highest common frequency.
No error is generated – this is not an error condition.
Continues to boot the system successfully.
If the frequencies for all processors cannot be adjusted to be the same,
then the BIOS:
Logs the error into the SEL.
Displays "0197: Processor 0x family is not supported" message in the
Error Manager.
Halts the system and will not boot until the fault condition is remedied.
Halt
The BIOS detects the error condition and responds as follows:
Adjusts all processor QPI frequencies to highest common frequency.
No error is generated – this is not an error condition
Continues to boot the system successfully.
If the link speeds for all QPI links cannot be adjusted to be the same, then
the BIOS:
Logs the error into the SEL.
Displays "0195: Processor 0x Intel® QPI speed mismatch" message
in the Error Manager.
Halts the system and will not boot until the fault condition is remedied.
Intel order number E81443-002
Intel® Server System SC5650HCBRP TPS
System Action
Revision 1.2