Intel SC5650HCBRP Product Specification page 205

Hide thumbs Also See for SC5650HCBRP:
Table of Contents

Advertisement

Intel® Server System SC5650HCBRP TPS
T: Threshold value
-
Rearm Sensors
The rearm is a request for the event status of a sensor to be rechecked and updated
upon a transition between good and bad states. You can rearm the sensors manually or
automatically. This column indicates the type supported by the sensor. These
abbreviations are used in the comment column to describe a sensor:
A: Auto-rearm
-
M: Manual rearm
-
I: Rearm by init agent
-
Default Hysteresis
The hysteresis setting applies to all thresholds of the sensor. This column provides the
count of hysteresis for the sensor, which is 1 or 2 (positive or negative hysteresis).
Criticality
Criticality is a classification of the severity and nature of the condition. It also controls the
behavior of the Control Panel Status LED.
Standby
Some sensors operate on standby power. You can access these sensors and / or
generate events when the main (system) power is off but AC power is present.
Revision 1.2
Intel order number E81443-002
Appendix C: BMC Sensor Tables
189