Intel SC5650HCBRP Product Specification page 213

Hide thumbs Also See for SC5650HCBRP:
Table of Contents

Advertisement

Intel® Server System SC5650HCBRP TPS
Full Sensor Name
Sensor #
(Sensor name in SDR)
Processor 1 Thermal Margin
62h
(P1 Therm Margin)
Processor 2 Thermal Margin
63h
(P2 Therm Margin)
Processor 1 Thermal
Control %
64h
(P1 Therm Ctrl %)
Processor 2 Thermal
Control %
65h
(P2 Therm Ctrl %)
Processor 1 VRD Temp
66h
(P1 VRD Hot)
Processor 2 VRD Temp
67h
(P2 VRD Hot)
Catastrophic Error
68h
(CATERR)
CPU Missing
69h
(CPU Missing)
IOH Thermal Trip
6Ah
(IOH Thermal Trip)
Note 1: Sensor only present on systems that have applicable redundancy (for instance, a fan or power supply).
Revision 1.2
Platform
Event /
Sensor Type
Applicability
Reading Type
Temperature
Threshold
All
01h
01h
Dual
Temperature
Threshold
processor
01h
01h
only
Temperature
Threshold
All
01h
01h
Dual
Temperature
Threshold
processor
01h
01h
only
Digital
Temperature
Discrete
All
01h
05h
Digital
Dual
Temperature
Discrete
processor
01h
only
05h
Digital
Processor
Discrete
All
07h
03h
Digital
Processor
Discrete
All
07h
03h
Digital
Temperature
Discrete
All
01h
03h
Intel order number E81443-002
Contrib. To
Event Offset
Assert /
System
Triggers
De-assert
Status
As and
[u] [c,nc]
Non-fatal
As and
[u] [c,nc]
Non-fatal
01 - Limit
As and
Fatal
exceeded
01 - Limit
As and
Fatal
exceeded
01 – State
As and
Non-fatal
Asserted
01 – State
As and
Fatal
Asserted
01 – State
As and
Fatal
Asserted
Appendix C: BMC Sensor Tables
Readable
Event
Rearm
Value /
Data
Offsets
Analog
Analog
Analog
Trig Offset
De
Analog
Trig Offset
De
Trig Offset
De
Trig Offset
De
Trig Offset
De
Trig Offset
De
Trig Offset
De
Stand-
by
A
A
M
M
M
M
M