Intel® Server System SC5650HCBRP TPS
8.5.3
SATA Connectors
The server board provides up to six SATA connectors: SATA-0 (J1G5), SATA-1 (J1G4), SATA-
2 (J1G1), SATA-3 (J1F4), SATA-4 (J1F1), and SATA-5 (J1E3).
The pin configuration for each connector is identical and defined in the following table.
Table 106. SATA / SAS Connector Pin-out (J1E3, J1G1, J1G4, J1G5, J1F1, J1F4)
Pin
1
2
3
4
5
6
7
8.5.4
SAS Module Slot
The server board provides one SAS module slot (J2J1) to support the Intel
Module AXX4SASMOD card. The following table defines the pin-out.
Pin
1
P3V3_AUX
3
SW_RAID_MODE
5
PE_ICH10_SAS_SW_C_TP0
7
GND
9
PE_ICH10_SAS_SW_C_TP1
11
GND
13
PE_ICH10_SAS_SW_C_TN2
15
GND
17
PE_ICH10_SAS_SW_C_TN3
19
GND
21
PE_WAKE_N
23
P3V3
25
P3V3
27
GND
29
PE_ICH10_SAS_SW_RXN0
31
GND
33
PE_ICH10_SAS_SW_RXN1
Revision 1.2
Signal Name
GND
SATA TX_P_C
SATA TX_N_C
GND
SATA _RX_N_C
SATA _RX_P_C
GND
Table 107. SAS Module Slot Pin-out (J2J1)
Name
Intel order number E81443-002
Connector/Header Locations and Pin-outs
Description
Ground
Positive side of transmit differential pair
Negative side of transmit differential pair
Ground
Negative side of receive differential pair
Positive side of receive differential pair
Ground
Pin
2
RST_LPC_SAS_N
4
GND
6
PE_ICH10_SAS_SW_C_TN0
8
GND
10
PE_ICH10_SAS_SW_C_TN1
12
GND
14
PE_ICH10_SAS_SW_C_TN2
16
GND
18
PE_ICH10_SAS_SW_C_TN3
20
FM_SAS_PRSNT_N
22
FM_SAS_RST_N
24
PE_RXN<2>
26
P3V3_AUX
28
PE_ICH10_SAS_SW_RXP0
30
GND
32
PE_ICH10_SAS_SW_RXP1
34
GND
®
SAS Entry RAID
Name
157