Procedure
Note: The power entry module on this EFX is a multifunction unit. It functions as a power entry
module, A.C. line fuse holder, on/off switch and A.C.line filter.
1.
Set the on/off switch in the off position. Remove the A.C. line cord from the A.C. outlet and
from the power entry module.
2.
Remove the left and right hand cover sections per Procedure 7.1.
Diagram 7.3 - Power Entry Module
Fuse
Access Door
On/Off
Switch
A.C. Input
3.
Remove the blue wire from terminal D, the brown wire from terminal A and the green wire
from the ground terminal of the power entry module.
4.
Remove the two screws that fasten the power entry module to the bottom cover. Remove
the power entry module from the bottom cover.
5.
Open the fuse compartment and remove both fuses (See Procedure 7.24). Check both
fuses with an ohmmeter. They should read approximately 1Ω or less. Replace any fuse that
reads significantly high.
6.
Install the tested fuses, from step 5, in the replacement power entry module.