Mitsubishi CR800 Series Instruction Manual page 71

Table of Contents

Advertisement

Error No.
H7861
One of the errors below is detected.
Please take measures corresponding to an error message.
Error message SLMP parameter error
Cause
Measures
Error message SLMP SLMPPORT parameter error
Cause
Measures
Error message SLMP SLMPPORT parameter error
Cause
Measures
L8300
Error message There are a lot of GETPOS define
Cause
Measures
L8310
Error message GETPOS undefined
Cause
Measures
H8320
Error message System Error (GETPOS)
Cause
Measures
H8400
Error message CTN data is illegal (Prec)
Cause
Measures
H8410 *
Error message DEVICENET Card failure
Cause
Measures
H8420 *
Error message DEVICENET Mode switch is outside
Cause
Measures
H8421 *
Error message DEVICENET Unit number switch is outside
Cause
Measures
H8430
Error message DEVICENET Communication error
Cause
Measures
H8440
Error message DEVICENET Unit number overlaps
Cause
Measures
H8441
Error message DEVICENET Network power failure
Cause
Measures
H8442
Error message DEVICENET Other units not found
Cause
Measures
H8450
Error message DEVICENET Install more than one
Cause
Measures
Illegal parameter.
Correct parameter.
Overlap with server port number of NETPORT.
Please set not to overlap to another port number.
Overlap with element of NETPORT(1) or MONPORT(1/2).
Please set not to overlap to another port number.
GETPOS function are up to 8.
Please use the same Act No. or reset an unnecessary program.
GETPOS undefined.
Please define GETPOS.
Internal data of GETPOS is illegal.
Turn the power OFF and ON once.
CTN data is illegal. It changed to Prec Off.
Try to set be a Prec mode again.
Abnormality of the DEVICENET card is detected.
Please exchange the DEVICENET card.
When replacing the card, contact its manufacturer for advice.
The mode switch is outside.
Please correct the mode switch.
The unit number switch is outside.
Please correct the unit number switch.
Network fail or Master setting is illegal.
Please confirm the network (speed, cable, terminator) or the master unit.
There are more than one unit with the same unit number on the network.
Please confirm the other unit number.
Network power is turned off.
Please turn on network power.
Other units are not connected on the network.
Please confirm the other units.
Only one 2D-TZ571 card can be installed.
Please install only one 2D-TZ571 card.
Error cause and measures
1Error list
1-62
Error no. H7861