Mitsubishi CR800 Series Instruction Manual page 51

Table of Contents

Advertisement

Error No.
L3260
Error message Cannot exec for all slots
Cause
Measures
L3270
Error message The command size is exceeded
Cause
Measures
L3280
Error message Cannot execute without GetM
Cause
Measures
L3281
Error message Cannot execute during RUN
Cause
Measures
L3282
Error message "Can't RUN (not select, attribute)"
Cause
Measures
L3285
Error message Cannot execute (RUN or WAI)
Cause
Measures
L3286
Error message Program is empty
Cause
Measures
L3287
Error message Cannot execute (ERROR ALWAYS)
Cause
Measures
L3288
Error message Cannot execute while editing
Cause
Measures
L3289
Error message Program does not exist (SLT*)
Cause
Measures
L3290
Error message System slot cannot be executed
Cause
Measures
L3300
Error message User slot cannot be executed
Cause
Measures
L3310
Error message Cannot execute XRun (Runing)
Cause
Measures
L3320
Error message Cannnot execute XRun (empty)
Cause
Measures
L3330
Error message Cannnot execute XStp (empty)
Cause
Measures
L3340
Error message Cannnot execute XRst (empty)
Cause
Measures
Execution with all slots designated is not possible.
Designate an individual slot and try again.
The command size is exceeded.
Specify within single-byte 256 characters.
The command you attempted to execute cannot be executed without GetM. Or, a non-existing mechanical
number was specified.
Execute it after executing the RelM and GetM commands in another task slot.
Cannot execute during operation.
Cannot execute during operation.
The program is not selected or the attribute is illegal.
Load the program into the specified task slot. Or, change the program attributes.
can't execute in the state of stopping or executing.
Reset the program (cancel the abort status).
Execution of an empty program was attempted.
Make the program or select the correct program.
This command cannot be used when the start conditions are ERROR and ALWAYS.
Correct the program.
That program cannot be executed because it is being edited.
Finish editing the program first, and then start it.
The program designated in the slot table does not exist.
Correct the slot parameter.
The system slot cannot be executed.
Check whether another slot (user slot) is being operated.
A user slot cannot be executed.
Check whether the system slot is being operated.
XRun is not possible as the designated slot is operating.
Stop the specification slot, and execute.
XRun is not possible as the program has not been selected.
Specify program name to the argument or execute XLoad.
XStp is not possible as the program has not been selected.
correct the program, and execute.
XRst is not possible as the program has not been selected.
Resetting is possible in the state of waiting only.
Error cause and measures
1Error list
1-42
Error no. L3260

Hide quick links:

Advertisement

Table of Contents
loading