1Error list
Error No.
L3350
Error message Cannnot execute XRst (Running)
Cause
Measures
L3360
Error message Cannnot execute XLoad (not PSA)
Cause
Measures
L3361
Error message Can not load the program (SLT*)
Cause
Measures
L3370
Error message Cannnot execute XClr (empty)
Cause
Measures
L3380
Error message Cannnot execute XClr (not PSA)
Cause
Measures
L3390
Error message Cannot use arc pallet
Cause
Measures
L3391
Error message Cannot use MVA2
Cause
Measures
L3400
Error message System error (PROC stack over)
Cause
Measures
L3500
Error message Illegal format input (Input)
Cause
Measures
L3501
Error message Illegal Receive data (EBREAD)
Cause
Measures
L3510
Error message Failed to receive data
Cause
Measures
L3600
Error message Jump destination does not exist
Cause
Measures
L3601
Error message Jump destination is incorrect
Cause
Measures
L3700
Error message Undefined variable
Cause
Measures
L3710
Error message Nesting over (CallP)
Cause
Measures
L3720
Error message RC NX statements unmatch
Cause
Measures
1-43
Error no. L3350
Xrst is not possible as the program is executing.
Stop execution, and do it.
XLoad cannot be executed when the program cannot be selected.
Execute XRst, and do it.
A non-existing program was specified in the slot parameter (SLTn).
A non-existing program was specified in the slot parameter (SLTn).
XClr is not possible as the program has not been selected.
XClr can only be executed to enable program selection.
Program selection is not enabled.
Execute XClr after resetting the program (canceling the abort status).
Cannot use arc pallet.
Change to another method.
Cannot use MVA2
Change to another method
System error. (Processor stack overflow)
If it comes back, contact your service provider
The type of the variable specified by Input and the type of the received data do not match.
Check the format.
Type is different (receive data and specified variable)
Please confirm specified tag data of the vision.
Unprocessed received data size has exceeded receive buffer limit.
Check data sending / receiving timing, and processing procedure.
No jump destination was found for the Def Act, On Com and On GoTo commands.
Check the jump destination.
Jumping into program control block is prohibited.
Correct the program and re-execute.
It was attempted to reference a variable that has not been initialized.
Define a variable, enter an initial value, and then use it.
Program Call is used more than the limitation.
Reduce the call count of CallP (nesting).
RC NX statements unmatch
Match the numbers of RC and NX.