Hardware procedures
CAUTION
Risk of equipment damage
To prevent equipment damage, disconnect the cables attached to
the ports of an FP before you disconnect the control cable that
connects the FP to a termination panel.
Disconnect any cables from the FP faceplate. See the figure
connectors used on Multiservice Switch processor cards (page
If you are removing an FP that uses optical connections, cap the optical
ports with an appropriate dust boot.
Unlock the upper and lower card latches. See the figure
unlocking processor card latches (page
Move both latches to a fully horizontal position and use the latches to pull
the FP card out of the slot. Refer to the figure
(page
250).
WARNING
Damage to equipment by electromagnetic interference
To meet electromagnetic interference (EMI) regulatory requirements
and thermal specifications, each empty slot must be filled with a
blank processor card (NTBP23). See
card (page
168).
Pack the FP according to
Packing a processor card (page
whether a failed FP is being returned to Nortel Networks or the card is being
re-deployed.