Procedure job aid
Inter-panel flexi-cable for MSA32 and MSA8 sparing panels with RJ-45 connectors
Sliding latch
Copyright © 2005, Nortel
- 294 -
Hardware procedures
Holding the end of another flexi-cable that has one D-sub connector (not
two), align and plug the D-sub into the third D-sub connector on the
underside of the sparing panel. Allow the cable to hang freely.
Repeat
step 10
for the remaining 3 flexi-cables.
For each remaining sparing panel in the 1:n series up to but not including
the Main A (bottom) panel, repeat step 5 to step 11 continuing downwards.
Install the last (bottom) RJ-45 sparing panel the same as the previous one.
Below the panel, leave a vertical space equal to the height of 3 panel
faceplates. Allow the flexi-cables from the panel above to be pushed back
by this panel.
Connect and fasten the hanging flexi-cable D-subs from the sparing panel
above the Main A into the underside of Main A. Fasten each D-sub as before
except for each third D-sub connector, fasten them to the posts using the
hex fasteners (not the stud fasteners).
Nortel Multiservice Switch 7400
Hardware Installation, Maintenance, and Upgrade
NN10600-175 7.1S1 Standard
PCR7.1 and up October 2005
--End--