Database requirements for Incoming DID Digit Conversion

The following information replaces the information about the feature Incoming DID Digit
Conversion in NTP Section 553-3001-306 – Software Features Guide.
Note: The following inputs are samples only; they most likely will differ for your specific
configuration.
All of the steps below are performed on the Meridian 1 PBX using a terminal connection.
1
At the main prompt type, LD 15.
2
Respond to the prompts according to
Table 9 Specify the maximum number of incoming Digit Conversion trees allowed
Prompt
Response
REQ
CHG
TYPE
CDB
FCR_DATA
CUST
0-99
0-31
- NFCR
(NO) YES
- MAXT
1-255
- IDCA
(NO) YES
- DCMX
1-255
Print Customer Data Block - Overlay 21
REQ prt
TYPE FCR
FCR_DATA
NFCR YES
MAXT 1
OCB1 255
OCB2 255
OCB3 255
IDCA YES
DCMX 1
3
At the main prompt type, LD 49.
Chapter 5 Initializing the CallPilot Mini
Table
9.
Comment
Change
Customer Data Block
New Flexible Code Restrictions Option
Customer number
For Option 11C
(Disable) Enable New Flexible Code Restriction (NFCR)
Maximum number of NFCR trees
(Disable) Enable IDC
Maximum number of IDC tables
Note: The sum of the values for MAXT and DCMX cannot exceed 255
per customer.