BayStream 7.3 Documentation Change Notice
To initiate a loopback test using Test Traffic Generation, perform the following
steps:
Attach the loopback device at the destination end of the cable connection
1.
of the port you will test.
Use the Technician Interface commands shown in
2.
generation on a specific type of line.
Monitor the line send and receive counter increments if the loop
3.
completes successfully.
During the loopback test:
To disable Test Traffic Generation, use the Technician Interface
4.
commands shown in
For example, use the following command to disable a HSSI line:
set wfHssiEntry.wfHSSIBofl.slot.connector 2; commit
Table 7.
Link Module
Qsync
Osync
HSSI
MCT1
Using Site Manager to Reallocate Memory Partitions for a Processor
Module
This section supplements the "Memory or Buffer Problem" section on page 3-13
of Troubleshooting and Testing.
50
wfFrSwDlcmiEntry.wfFrSwDlcmiState remains in the init or down state.
Line status remains in the lineloopbofltest state.
While Test Traffic Generation is enabled, the link management interface
remains down.
Table 7
Technician Interface Commands Used to Enable Test Traffic
Generation
Technician Interface Command
set wfSyncEntry.wfSyncBofl.slot.connector 1; commit
set wfSyncEntry.wfSyncBofl.slot.connector 1; commit
set wfHssiEntry.wfHssiBofl.slot.connector 1; commit
set wfLogicalLineEntry.wfLogicalLineBofl.
PortLineNumber.LineIndex 1; commit
BayStream Multiservice Software Version 7.3
to set the MIB values to 2.
Table 7
to enable test