Non-Volatile File System (NVFS) Events

Entity Code/Event Code
Decimal Identifier
Severity:
Warning
Message:
DRAM VFS on slot <slot_no.>: insufficient memory; requested size <size>, available size
<size>
Meaning:
The specified slot does not have enough available memory to accommodate the requested
size of the DRAM VFS file system.
Action:
Change your requested size to one that is equal to or less than the amount of memory
available.

Telnet Server Protocol (TELNET)

Entity Code/Event Code
Decimal Identifier
Severity:
Warning
Message:
Dynamic Port Prefix is out of range. Port Prefix set to <value>. Valid value must be 0, or
between <value>-<value>.
Meaning:
The dynamic port prefix is invalid.
Action:
Change the port prefix to a value within the valid range.

STATS to DRAM

Entity Code/Event Code
Decimal Identifier
Severity:
Warning
Message:
No room for STATS file on volume - < slot_no.>.
Meaning:
The statistical data collection file requires more space than is available in the volume, so it
could not write the performance file to the <DRAM VFS>.
Action:
Retrieve the accumulated files from < DRAM VFS>, and compact the storage media.