Using Site Manager

To use Site Manager to configure a local port prefix, perform the following steps:
You do this
1. In the Configuration Manager window,
choose Protocols.
2. Choose Global Protocols.
3. Choose Telnet Server.
4. Choose Global.
5. At the Edit Telnet Server Global
Parameters window, set the following
parameter:
Local Port Prefix
6. Click on OK.

Using the Technician Interface

Use the Technician Interface command shown in
port prefix.
Figure 13.
[4:1] $ set wfTelnet.wfTelnetLocPrtPrefix.11
115385-D Rev 01
Configuring a Local Port Prefix
TI set command
Telnet MIB Entry
BayStream Multiservice Software Version 7.3
BayStream 7.3 Documentation Change Notice
Site Manager Procedure
System responds
The Edit Telnet Server Global
Parameters window opens.
Valid values are 11 through 166.
To disable the local port prefix
feature, set the parameter to 0.
Site Manager returns you to the
Configuration Manager window.
Figure 13
attribute identifier
value (11 through 166; 0=disable)
to configure a local
BYS0098A