4.
Loopback Corrected (Normal Condition)
A normal condition exists when the DCE that is reporting a loopback condition
sends two consecutive status enquiry messages in which each of the received
status message's send sequence numbers have been increased by one.
BayStream software generates a severity level warning log message (for example,
cct2, Loopback condition corrected).
Enabling Loopback Detection Using Site Manager
To enable loopback detection, perform the following steps:
You do this
1. In the Configuration Manager window,
choose Protocols.
2. Choose Frame Relay Switch.
3. Choose Interfaces.
4. Select an interface.
5. Choose Edit.
6. Set the following parameters:
•
LoopBack Enable: Enabled
•
Bidirectional Enable: Enabled
7. Choose Save.
8. Click on Done.
115385-D Rev 01
If the Cross Net or Asynchronous Cross Net feature is enabled, BayStream
software sends an update message to the DCE (one message for each PVC
and one message for each SVC) at the other end to notify the DCE that the
interface has been torn down.
BayStream Multiservice Software Version 7.3
BayStream 7.3 Documentation Change Notice
Site Manager Procedure
System responds
Site Manager displays a list of
frame relay switch interfaces.
The Edit FRSW Interface window
opens.
Site Manager returns you to the
list of frame relay switch
interfaces.
Site Manager returns you to the
Configuration Manager window.
37