240
Hardware Maintenance Manual: xSer ies 380
Code/Explanation
050Bh SCSI spin down test failed
050Ch Error in disk partition table
050Dh Boot sector error. The boot
partition has an incorrect definition
050Eh Media error. The media
description for the partition is bad.
The unit is not properly OS
formatted
050Fh The sector number
information in the partition table is
wrong. The unit is not properly OS
formatted
0510h No Tape in the drive
0511h Positioning failed on tape
drive
0512h Tape read error
0513h Tape write error
FRU/Action
1.
Confirm that drive is configured
2.
Check drive cables and connections
3.
Drive
4.
System I/O Board or SCSI add-on controller
1.
Confirm that drive is formatted and configured
2.
Check drive cables and connections
3.
Drive
4.
System I/O Board or SCSI add-on controller
1.
Confirm that drive is formatted and configured
2.
Check drive cables and connections
3.
Drive
4.
System I/O Board or SCSI add-on controller
1.
Confirm that drive is formatted and configured
2.
Check drive cables and connections
3.
Drive
4.
System I/O Board or SCSI add-on controller
1.
Confirm that drive is formatted and configured
2.
Check drive cables and connections
3.
Drive
4.
System I/O Board or SCSI add-on controller
1.
Check if a tape is in drive
2.
Confirm that drive is configured
3.
Check drive cables and connections
4.
Drive
5.
System I/O Board or SCSI add-on controller
1.
Confirm that drive is configured
2.
Check drive cables and connections
3.
Drive
4.
System I/O Board or SCSI add-on controller
1.
Check if write test has been executed
2.
Confirm that drive is configured
3.
Check drive cables and connections
4.
Drive
5.
System I/O Board or SCSI add-on controller
1.
Confirm that drive is configured
2.
Check drive cables and connections
3.
Drive
4.
System I/O Board or SCSI add-on controller

Advertisement