IBM xSeries 380 Hardware Maintenance Manual page 157

Table of Contents

Advertisement

To maintain proper system cooling, do not operate the server for more than 10
minutes without either a drive or a filler panel installed in each bay.
To secure a hard disk drive into the drive tray you must have four screws, 5/16"
long with a #2 phillips drive recess.
Determining drive status
Status LEDs arranged in sets of three over each of the two bays monitor the status of
each drive. See "Controls and indicators" on page 7 for a description of the LEDs.
Table 13. SCSI Drive Status LED Descriptions.
SCSI Drive Present,
Power On
(Green LED)
On
On
Off
On
Off
Removing a hard disk drive
Complete the following actions to remove a hard disk drive.
1.
Examine the amber LEDs above the Hard Drive Bays to determine which drive
has failed. See Table 13 for information on how to interpret the LEDs.
2.
Remove the plastic bezel on the front of the server.
Push on the drive carrier latch ( 1 ) of the failed drive and use the handle to pull
3.
the assembly toward you.
SCSI Drive
SCSI Drive
Active
Faulty
(Green LED)
(Amber LED)
Off
Off
Blinking
Off
Off
On
Off
Blinking slowly
Off
Off
Description and Action If
Needed
Drive is present with power.
Drive is present with power and
is being accessed.
Steady amber fault light
indicates drive has a problem.
Drive SHOULD NOT be
replaced at this time. A slowly
blinking amber fault light
indicates that a newly-replaced
drive is in recovery mode (drive
array being rebuilt). Power to
drive is on.
There is no drive installed in the
bay.
Installing components
147