Hardware Maintenance Manual: xSer ies 380
CAUTION:
Hazardous voltage, current, and energy levels might be present. Only a
qualified service technician is authorized to remove the covers where the
following label is attached.
If the system is rack-mounted, pull the chassis out of the rack to expose the
Processor/Memory Bay on the right side of the chassis as you face its front.
Statement 15
CAUTION:
Make sure that the rack is secured properly to avoid tipping when the server
unit is extended.
Loosen the two screws ( 1 ) on the left side of the Processor/Memory Complex
cover located on the right side of the chassis as you face its front. Loosening these
screws causes the left side of the cover to spring open.
Grasp the cover and press it back toward the chassis as you shift the cover to the
left. Shifting the cover to the left clears the right side of the cover from behind the
chassis side.
Once the cover is clear of the chassis, set it aside.