234
Hardware Maintenance Manual: xSer ies 380
Error Code/Explanation
0102h System BIOS cannot set
the year to 2000 after 12/31/99.
0120h Parity error at absolute
memory location XXXXXXXXh.
AMIDiag found a parity error at
xxxxxxxxh.
0130h The pattern written at
XXXXXXXXh was qqqqh. The
pattern read back from that
address was pppph. AMIDiag
wrote a pattern to address
xxxxxxxxh. A different value
was read back.
0131h Parity failure at
XXXXXXXXh during pattern
test. While performing the
pattern test to the specified
address, AMIDiag receiv ed a
parity error.
0132h Faulty memory chip on
SIMMM xxxx
0135h ECC correctable error in
SIMM sockets xxxx/yyyy
0136h ECC uncorrectable error
in SIMM sockets xxxx/yyyy
0137h Error occurred on bank
XXXX interleave YYYY
0140h Failure at address
XXXXXXXXh, bit position bbh.
A failure occurred at the
specified address.
0150h Failure at XXXXXXXXh,
bit position bbh. A failure
occurred at the specified
address.
0160h There is an address short
between bit xxh and yyh.
AMIDiag detected a short in the
address lines between the bits
specified above. For example, if
Address short found between
bit 01h and 02h
appeared, address lines A0 and
A1 have a short between them.
0170h RAM Refresh is not
working. The system RAM
refresh signal is either not being
generated or the signal is being
generated sporadically.
FRU/Action
1.
Replace System BIOS
1.
Reseat Memory DIMMs
2.
Memory Board
1.
Reseat Memory DIMMs
2.
Memory Board
1.
Reseat Memory DIMMs
2.
Memory Board
1.
Reseat Memory DIMMs
2.
Memory Board
1.
Reseat Memory DIMMs
2.
Memory Board
1.
Reseat Memory DIMMs
2.
Memory Board
1.
Reseat Memory DIMMs
2.
Memory Board
1.
Reseat Memory DIMMs
2.
Memory Board
1.
Reseat Memory DIMMs
2.
Memory Board
1.
Reseat Memory DIMMs
2.
Memory Board
1.
Legacy I/O Board