4.4.3 Connecting FCUA-DX10x/14x Unit with Machine Control Signal

Machine
signal
Machine
signal
<Outline of connection>
Connection to 24V common (example)
DI-L
A3
24VDC(+)
B3
0V
(RG)
B1
B2
A1
A2
24VDC(+)
DO-L
RA
R
PL
B1
B2
Machine
A1
control panel
A2
RIO1
Stabilized power supply
CAUTION
1. Connect the cable to the designated connector. Incorrect connections could damage the device.
2. Do not connect or disconnect the connection cables between each unit while the power is ON.
Type of machine input/output signal and
number of points
FCUA-R300 /
FCUA-R301
FCUA-R300 /
FCUA-R301
FCUA-DX100/140
COM
Input circuit
Sink type
Output circuit
Sink type
Control
circuit
DCIN
RIO2
1 2 3
24VDC(+)
0V FG
Input
Output
32 points
32 points
DI-L
DO-L
Connection to 0V common (example)
DI-L
A3
0V(RG)
B3
24VDC(+)
B1
B2
A1
A2
DO-L
RA
R
PL
B1
0V(RG)
B2
Machine
A1
control panel
A2
Stabilized power supply
FG
M70V Series Connection Manual
4.4 Connection of Remote I/O Unit
FCUA-DX10x
or
FCUA-DX14x
FCUA-DX101/141
COM
Input circuit
Sink type
Output circuit
Sink type
Control
circuit
DCIN
RIO1
RIO2
1 2 3
24VDC(+)
0V FG
FG
137