Connecting With Synchronous Feed Encoder/ Manual Pulse Generator; Handle Numbers - Mitsubishi Electric M70V Series Connection Manual

Table of Contents

Advertisement

4.2.10 Connecting with Synchronous Feed Encoder/ Manual Pulse Generator

Synchronous feed encoder (1ch) or 5V power supply type manual pulse generator (2ch) can be connected.
ENC
<Related items>
Cable drawing: "Cable: FCUA-R050/R054 Cable" and "Cable: G023/G024 Cable"
Connector pin assignment: "General Specifications: Control Unit" (ENC connector)
When using the synchronous feed encoder and the manual pulse generator at the same time, the cables must be
prepared by the machine tool builder.

4.2.10.1 Handle Numbers

Unit configuration decides handle Nos.
"ENC": Connector on control unit "MPG": Connector on operation panel I/O unit
Operation panel I/O unit (FCU7-DX71x/ DX72x/ DX73x/DX621)
Used
Not used
(Note)
If one handle is only connected to "MPG", the handle connected to "ENC" 1ch will still be treated as the 3rd
handle. "ENC" 2ch is not employed when an operation panel I/O unit is used.
R054 cable
R050 cable
When connecting one 5V
manual pulse generator
G023 cable
When connecting two 5V
manual pulse generators
G024 cable
1st handle
"MPG" 1ch
"ENC" 1ch
M70V Series Connection Manual
4.2 Connection of Control Unit
Synchronous feed encoder
OSE1024-3-15-68
<Right angle>
5V manual pulse generator
(Rear view)
NO.1
5V   0V    A    B
NO.1
NO.2
5V   0V    A    B
5V   0V    A    B
5V manual pulse generator
(Rear view)
2nd handle
3rd handle
"MPG" 2ch
"ENC" 1ch (Note)
"ENC" 2ch
-
119