Appendix 1.25 Fcua-R050/R054 Cable - Mitsubishi Electric M70V Series Connection Manual

Table of Contents

Advertisement

MITSUBISHI CNC
Appendix 1 Cable

Appendix 1.25 FCUA-R050/R054 Cable

Max. cable length: 30m
Application: Synchronous encoder - control unit
[ENC1]
Plug: 10120-3000VL
Shell: 10320-52F0-008
Recommended manufacturer: 3M
(Note)
Fold the cable shield over the sheath, and wrap copper foil tape over it. Connect the wound copper foil
tape to GND plate of the connector.
176
ENC
ENC1
4
ENC1A (ENC2A)
14
ENC1A*(ENC2A*)
3
ENC1B (ENC2B)
13
ENC1B*(ENC2B*)
2
ENC1Z (ENC2Z)
12
ENC1Z*(ENC2Z*)
1
GND
11
GND
10
+5V
20
+5V
FG
Wire material: UL1061-2464
AWG24 × 12P
Recommended manufacturer:
Oki Electric Cable
FCUA-R050
FCUA-R054
A
N
C
R
B
P
K
H
[FCUA-R050 cable]
Connector: MS3106B20-29S
Cable clamp: MS3057-12A
Recommended manufacturer:
ITT Cannon
[FCUA-R054 cable]
Connector: MS3108B20-29S
Cable clamp: MS3057-12A
Recommended manufacturer:
ITT Cannon