4.4.4 Connecting FCUA-DX14x Unit with Analog Input/Output Signal

For the analog input/output signal, connect the FCUA-R031 cable to "AIO". Up to four input points and one output point
can be connected for the analog input/output signal. When manufacturing the FCUA-R031 cable, use the FCUA-CS000
connector set (optional, with both ends).
FCUA-R031
Analog I/F
Input/output circuit
Connector pin No.
AI0
12
AI1
Input
AI2
13
AI3
AO
Output
 
GND
11
GND
G ND
 
GND
15
CAUTION
1. Connect the cable to the designated connector. Incorrect connections could damage the device.
2. Do not connect or disconnect the connection cables between each unit while the power is ON.
FC UA-DX14x
150
2
150
150
3
150
R
220
7
1
5
0V (RG)
4.4 Connection of Remote I/O Unit
FCUA-DX14x
AIO  
ADC
 
R
DAC
0V (RG)
M70V Series Connection Manual
20
 
10
 
11
1
Pin No.
 
139