4.2.5.2 Connecting with MDS-DM2 Series

CAUTION
1.Connect the NC and the drive units by the optical communication cables. The distance between the NC and the
final drive unit must be within 30m and the bending radius within 80mm.
2.A spindle drive unit that controls the high-speed synchronous tapping (OMR-DD control) has to be connected
on the farther side from the NC than the subject synchronous tapping control.
Thus, if you use an MDS-DM2 unit for servo control of the high-speed synchronous tapping, combinable
spindle drive is that of the MDS-DM2 unit only.
(1) When using only MDS-DM2-SPV Series
(2) When using the MDS-D2 unit together
Connected
to the NC
POINT
For MDS-DM2-SPV Series, axis Nos. are fixed as follows.
1st axis : spindle
2nd axis : servo L axis
3rd axis : servo M axis
4th axis : servo axis (only MDS-DM2-SPV3)
Connected
to the NC
Optical
communication
cable
MDS-D2-V2
MDS-D2-SP
5th/6th axis
7th axis
(Final axis)
Optical
communication
CN4
cable
The optical communication cables from the NC to the
final drive unit must be within 30m.
M70V Series Connection Manual
4.2 Connection of Control Unit
MDS-DM2-SPV3
Spindle:1st axis
Servo:2nd/3rd/4th axis
MDS-D2-CV
MDS-DM2-SPV3
Spindle:1st axis
Servo:2nd/3rd/4th axis
CN4
109