Mitsubishi Electric M70V Series Connection Manual page 31

Table of Contents

Advertisement

MITSUBISHI CNC
1 System Configuration
Classification
[Operation panel I/O unit]
DI 24V/0V common input
DO Sink output
DI 24V/0V common input
DO Sink output
AO Analog output
DI 24V/0V common input
DO Sink output
DI 24V/0V common input
DO Source output
DI 24V/0V common input
DO Source output
AO Analog output
DI 24V/0V common input
DO Source output
[Remote I/O unit]
DI 24V/0V common input
DO Sink output
DI 24V/0V common input
DO Sink output
DI 24V/0V common input
DO Sink output
AO Analog output
DI 24V/0V common input
DO Sink output
AI Analog input
AO Analog output
DI 24V/0V common input
DO Source output
DI 24V/0V common input
DO Source output
DI 24V/0V common input
DO Source output
AO Analog output
DI 24V/0V common input
DO Source output
AI Analog input
AO Analog output
[Scan I/O card]
Sink type
Source type
6
Type
Components
Base card
FCU7-DX710
Terminator (R-TM)
Base card
FCU7-DX720
Terminator (R-TM)
Add-on card
Base card
FCU7-DX730
Terminator (R-TM)
Add-on card
Base card
FCU7-DX711
Terminator (R-TM)
Base card
FCU7-DX721
Terminator (R-TM)
Add-on card
Base card
FCU7-DX731
Terminator (R-TM)
Add-on card
FCUA-DX100
RX311
FCUA-DX110
RX311+RX321-1
FCUA-DX120
RX311+RX321
FCUA-DX140
RX311+RX341
FCUA-DX101
RX312
FCUA-DX111
RX312+RX322-1
FCUA-DX121
RX312+RX322
FCUA-DX141
RX312+RX341
HR347
HR347
HR357
HR357
Remarks
DI: 64-points 24V/0V common type
DO: 64-points sink type
MPG:2ch
Occupied stations (fixed): 1, 2, 7, 8
RIO3 extensible stations: 3, 4, 5, 6
DI: 96-points 24V/0V common type
DO: 80-points sink type
MPG:2ch
AO: 1 point
Occupied stations (fixed): 1, 2, 3, 7, 8
RIO3 extensible stations: 4, 5, 6
DI: 96-points 24V/0V common type
DO: 96-points sink type
MPG: 2ch
Occupied stations (fixed): 1, 2, 3, 7, 8
RIO3 extensible stations: 4, 5, 6
DI: 64-points 24V/0V common type
DO: 64-points source type
MPG:2ch
Occupied stations (fixed): 1, 2, 7, 8
RIO3 extensible stations: 3, 4, 5, 6
DI: 96-points 24V/0V common type
DO: 80-points source type
MPG:2ch
AO: 1 point
Occupied stations (fixed): 1, 2, 3, 7, 8
RIO3 extensible stations: 4, 5, 6
DI: 96-points 24V/0V common type
DO: 96-points source type
MPG:2ch
Occupied stations (fixed): 1, 2, 3, 7, 8
RIO3 extensible stations: 4, 5, 6
DI: 32-points 24V/0V common type
(photo coupler insulation)
DO: 32-points sink type (non-insulation)
Number of occupied stations: 1
DI: 64-points 24V/0V common type
(photo coupler insulation)
DO: 48-points sink type (non-insulation)
Number of occupied stations: 2
DI: 64-points 24V/0V common type
(photo coupler insulation)
DO: 48-points sink type (non-insulation)
AO: 1 point
Number of occupied stations: 2
DI: 32-points 24V/0V common type
(photo coupler insulation)
DO: 32-points sink type (non-insulation)
AI: 4 points
AO: 1 point
Number of occupied stations: 2
DI: 32-points 24V/0V common type
(photo coupler insulation)
DO: 32-points source type (non-insulation)
Number of occupied stations: 1
DI: 64-points 24V/0V common type
(photo coupler insulation)
DO: 48-points source type (non-insulation)
Number of occupied stations: 2
DI: 64-points 24V/0V common type
(photo coupler insulation)
DO: 48-points source type (non-insulation)
AO: 1 point
Number of occupied stations: 2
DI: 32-points 24V/0V common type
(photo coupler insulation)
DO: 32-points source type (non-insulation)
AI: 4 points
AO: 1 point
Number of occupied stations: 2
Scan DI/DO = 64 points/64 points
DI/DO = 32 points/32 points
Scan DI/DO = 64 points/64 points
DI/DO = 32 points/32 points

Advertisement

Table of Contents
loading

Table of Contents