Wiring For Source Type Output (Fcu7-Dx711/Dx721/Dx731) - Mitsubishi Electric M70V Series Connection Manual

Table of Contents

Advertisement

4.3.4.4 Wiring for Source Type Output (FCU7-DX711/DX721/DX731)

Operation panel I/O unit
(Card name : HN351/HN371/HN372)
CG32 (CG34,CG36)
24VDC
1B
2B
24VDC
3A
24VDC
3B
24VDC
4A
24VDC
24VDC
4B
20B
Y200
19B
Y201
18B
Y202
17B
Y203
16B
Y204
15B
Y205
14B
Y206
13B
Y207
12B
Y208
11B
Y209
10B
Y20A
9B
Y20B
8B
Y20C
7B
Y20D
6B
Y20E
5B
Y20F
Y210
20A
Y211
19A
Y212
18A
17A
Y213
16A
Y214
15A
Y215
Y216
14A
Y217
13A
Y218
12A
Y219
11A
Y21A
10A
Y21B
9A
Y21C
8A
Y21D
7A
Y21E
6A
5A
Y21F
GND
1A
GND
2A
(Note 1) Connect +24V to either or both of the flat connector 1B, 2B (24VDC). (*1)
(Note 2) Connect +24V (GND) to the flat connector 3A, 3B, 4A, 4B (24VDC). (*1)
Decide the number of 24VDCs to wire with regard to the total amount of each connector's maximum output
current and the voltage drop by the cables. The rated current is 1A per connector pin.
(Note 3) Connect 0V (GND) to the flat connector 1A, 2A (GND). (*2)
(Note 4) When large current flows due to small amount of connected load, fuse may be blown out or 24V power supply
voltage may drop. In order to secure the appropriate current value, watch the connected load.
*1 Additional wiring
M70V Series Connection Manual
4.3 Connection of Operation Panel I/O Unit
Machine side
24VDC
PL
PL
PL
RA
RA
PL
PL
PL
GND
*2 Additional wiring
129