Mitsubishi Electric M70V Series Connection Manual page 88

Table of Contents

Advertisement

The HR357 output circuit is a source type (source output).
Source type
(Machine side)
0V(RG)
CAUTION
1. Do not apply any voltage to the connector other than that specified in this manual. Failure to observe this
could cause bursting, damage, etc.
Output conditions
(Note 1) When using an inductive load such as a relay, always connect a diode (voltage resistance
(Note 2) When using a capacitive load such as a lamp, always connect a protective resistor (R=150Ω)
CF33
24VDC
RA
R
PL
Insulation method
Rated load voltage
Max. output current
Saturation voltage
Output delay time
100V or more, 100mA or more) in parallel to the load.
serially to the load to suppress rush currents. (Make sure that the current is less than the
above tolerable current including the momentary current.)
M70V Series Connection Manual
FCU6-HR3x7
Control
circuit
Non-insulation
24VDC
60mA/point
1.6V (standard)
40μs
2.7 Scan I/O Unit
63

Advertisement

Table of Contents
loading