Mitsubishi Electric M70V Series Connection Manual page 129

Table of Contents

Advertisement

MITSUBISHI CNC
4 Connection
<Drive unit (MDS-DJ-V1) external emergency stop: Example>
NC control unit
EMG
NC control unit
LG
Emergency stop input circuit
<Caution>
(1) External emergency stop cannot substitute the emergency stop signal which is input to NC.
It is a function which helps the NC emergency stop.
(2) When duplicating emergency stop input, wire the NC emergency stop input and the power supply unit external
emergency stop input from the same emergency stop switch.
104
F120
EMG
+24V
3
3
R
EMGIN
2
2
FG
1
1
Stabilized
power supply
Emergency
MDS-DJ
stop switch
CN9
R
5
20
MDS-DJ-V1
+24V
0V(LG)