MITSUBISHI CNC
2 General Specifications
(a) Skip signal input conditions
Use the input signal within the following condition ranges.
1
Input voltage at external contact ON
2
Input current at external contact ON
3
Input voltage at external contact OFF
4
Input current at external contact OFF
5
Input resistance
6
Input signal holding time (Ton)
7
Internal response time
8
Machine side contact capacity
Connection to 24V common
External signal
+24V
0V
Connection to 24V common
(Machine side)
S K IP
24VDC
Input
voltage
0V(RG)
Input
voltage
 
0V(RG)
C OM
22
20V or more, 25.2V or less
Ton
+24V
External signal
0V
Connection to 0V common
(Machine side)
24VDC
Control
circuit
24V common
6V or less
18V or more, 25.2V or less
6mA or more
2mA or less
Approx. 2.2kΩ
2ms or more
0.08ms or less
+30V or more, 16mA or more
Connection to 0V common
Ton
S K IP  
 
Input
voltage
Input
voltage
C OM  
 
0V(RG)
0V common
4V or less
Control
circuit

Advertisement