<Connection when the selector SW has 3 notches>
+5V
R
X72
R
X73
R
X74
R
X75
<Connection when relaying wiring to control panel>
[EXT]
A01
PON
B01
PONCOM
(0V)
A02
POFF
B02
POFFCOM
(0V)
A03
EMG
B03
EMGCOM
(24VDC)
A04
EMG
B04
EMGCOM
(24VDC)
A05
B05
2.12 MITSUBISHI CNC Machine Operation Panel
[SUBP]
A13
B13
A14
B14
A15
2a2b Manual return type
B15
A16
B16
A17
B17
P-ON
A18
B18
P-OFF
A19
B19
A20
B20
Push button SW
(For emergency stop)
Push Lock -
Turn Reset
2a2b contact
M70V Series Connection Manual
Selector SW
3 notch
Connection with
P-ON/OFF Switch
Connection using two contacts
of emergency switch