System Configuration

1-2

System Configuration

Dedicated
terminal block
Note
The system configuration for the NC Units is given below with the CS1W-
NC413/433 used as a representative example. The CS1W-NC213/233 and
CS1W-NC113/133 are used for control of 2 axes and 1 axis respectively.
CPU Unit
NC Unit
(CS1 Series)
(CS1W-NC413/433)
Dedicated
terminal block
External inputs
CCW limit input
CW limit input
Origin input
Origin proximity input
Emergency stop input
Interrupt input
Interface power
supply (24 V)
Stepping
motor
drivers
or
Servomotors
Stepping motors
1. Special cables are available to connect OMRON U-series Drivers, W-se-
ries Drivers, or Smart Step A-series Drivers. Cables made by the user can
also be used.
2. Special cables are available for connections to special terminal blocks. Ca-
bles made by the user can also be used.
3. A battery for data backup is required when using an absolute encoder.
Power Supply Unit
Host Link
Host Link
External inputs
CCW limit input
CW limit input
Origin input
Origin proximity input
Emergency stop input
Interrupt input
Stepping
Servomotor
motor
drivers
drivers
Stepping motors
Section 1-2
CX-Programmer
Creation and
transfer of ladder
programs,
monitoring, file
management, etc.
CX-Position
Creation and
transfer of data, NC
Unit monitoring, file
management, etc.
Interface power
supply (24 V)
Servomotor
driver
or
Servomotors