On the project tree, either double-click Edit Dwell Time, or select it and press
the Enter Key.
Example: The following will be displayed as the 4-axis NC Unit Dwell Time
Setting Editing Screen.
The dwell time setting range is from 0000 to 03E7 Hex (0.00 to 0.99) (s).
Refer to 4-2-2 Editing Settings for editing methods.
Example: The following will be displayed as the Dwell Time Setting Editing
Screen.
Use the following procedure to clear specific settings to their default values.
(Refer to 4-2-4 Clearing Settings for details.)
1. On the dwell time Setting Editing Screen, select the settings to be cleared
to their default values, or designate the range by clicking and dragging.
2. Select Edit/Clear
For 2-axis and 4-axis NC Units, data can be copied from one axis to another
axis by selecting the source and destination axes. (Refer to 4-2-5 Copying
Axis Settings for details.)
1. Select Edit/Copy Axis.
2. Under From and To, select the axes to be copied from and to respectively.
3. Click the OK Button.