Please read and understand this catalog before purchasing the
products. Please consult your OMRON representative if you have any
questions or comments. Refer to "Warranty and Application
Considerations" on page 36, and "Precautions for Safe Use" on page 34.
Even Broader Applications with Increased
Functionality and Higher Precision
• Increased functionality in a compact body (70 mm wide × 90 mm
high).
• Easy programming is available using the LCD and operation
buttons. (See note 1.)
• This single Unit easily provides relay, timer, counter, and time
switch functions.
• Expansion is easy with Expansion I/O Units, allowing up to 44
I/O points. (See note 2.)
• Economy-type and Communications-type CPU Units have been
added to series.
• Improved Weekly Timers (See note 1.)
Increased timing accuracy with a monthly deviation of ±15 s
max. Multiple-day operation and pulse output operation have
been added.
• Select from two power supply options:
100 to 240 VAC or 12 to 24 VDC.
Note: 1. Not supported for ZEN-@C2@@-@-V2 models.
2. When using CPU Units with 20 I/O points.
Features
■ Easy and Simple Programming for Automatic Small-scale Control
Saves Space, Wiring, and Installation Steps
• Versatile functionality in a compact body (70 mm wide × 90 mm
high).
• This single Unit easily provides relay, timer, counter, and time
switch functions. Wiring work is greatly reduced because separate
wiring is not required for devices such as timers and counters.
The information in this document applies to V2 Units.
Refer to page 28 for details on differences with previous
products.
Easy Programming
The LCD screen comes with 8 operation buttons on the front panel to
enable programming in ladder view format. The LCD screen also has
a backlight, making it easier to see when the ZEN is used in dark
locations.
Note: Not supported for ZEN-@C2@@-@-V2 models.
90 mm
70 mm
Programmable Relay
ZEN V2 Units
1

Advertisement

loading

Summary of Contents for Omron ZEN V2

  • Page 1 The LCD screen also has • This single Unit easily provides relay, timer, counter, and time a backlight, making it easier to see when the ZEN is used in dark switch functions. Wiring work is greatly reduced because separate locations.
  • Page 2 • Programs can be simulated on the personal computer without enough I/O points. Expansion I/O Units are only 35 mm wide. connecting to the ZEN. Note: CPU Units with 10 I/O points can be expanded to 34 I/O points. Expansion I/O Units cannot be connected to Economy-type CPU Units.
  • Page 3 ■ Series Configuration CPU Units Power supply voltage: 100 to 240 VAC, 12 to 24 VDC, Output: Relay, transistor output With LCD display, operation buttons, and calendar/clock function LED type 10 I/O points 20 I/O points 10 I/O points 20 I/O points...
  • Page 4: Model Number Structure

    Note: Use a ZEN-8E@@/-4E@ to connect to pre-V1 and V1 CPU Units. This data sheet is provided as a guideline for selecting products. Be sure to refer to the following user manuals for application precautions and other information required for operation before attempting to use the product.
  • Page 5: Ordering Information

    ZEN-8E1DT (See note 2.) Note: 1. Programming is not possible using only the CPU in the LED-type CPU Unit. ZEN Support Software or a Memory Cassette is required. 2. Cannot be connected to pre-V1 and V1 CPU Units. 3. The ZEN-8E1AR cannot be connected to a CPU Unit with DC power supply.
  • Page 6 Support Software Note: 1. Up to 3 Expansion I/O Units can be connected to any type of CPU Unit except for Economy-type CPU Units. Expansion I/O Units with AC Inputs, however, cannot be connected to CPU Units with DC Power Supplies.
  • Page 7: Specifications

    0 to 55 ° C ( − 25 to 55 ° C for ZEN-@C2@@-@-V2 models) Ambient temperature Ambient storage temperature − 20 to 75 ° C ( − 40 to 75 ° C for ZEN-@C2@@-@-V2 models) Ambient humidity 10% to 90% (with no condensation)
  • Page 8 Expansion I/O Unit: Approx. 120 g max. Note: 1. Up to 34 points for CPU Units with 10 I/O points. With Communications-type CPU Units, however, the CPU Unit has 6 inputs and 3 outputs, for a maximum of 33 I/O points.
  • Page 9 Note: EMC conforms to EN 61131-2 clause 8 except in the following cases. • When Expansion I/O Units with DC inputs are connected to a CPU Unit with an AC power supply, the burst immunity between power supplies will be 1 kv.
  • Page 10 DC Inputs: I4 and I5 for Units with 10 I/O points, Ia and Ib for Units with 20 I/O Points (Not Isolated) Item Specifications Circuit drawing 12 to 24 VDC +20%, − 10% DC Inputs Input voltage 5.5 k Ω /14 VDC min.
  • Page 11 The life under the worst conditions, of the output contacts used in Life-test Curve (Reference Value) ZEN relay outputs is given in the above table. Guidelines for the Usage: 360 times/hour normal life of the relays are shown in the diagram on the right. 1,000 250-VAC resistive load 24-VDC resistive load/...
  • Page 12 Units with AC Power Supply Note: 1. Supply power to both the CPU Unit and Expansion I/O Units from the same power supply and turn them ON and OFF at the same time. 2. The input circuit commons for CPU Units with AC power supply are internally connected to the N terminal of the power supply circuit.
  • Page 13 ON the power supply, a malfunction may occur. 2. Apply the power supply voltage through a relay or switch in such a way that the voltage reaches the rated value within 4 s. If the voltage is applied gradually, the power may not be reset or unstable output operations may result.
  • Page 14 Expansion I/O Units Note: 1. Supply power to both the CPU Unit and Expansion I/O Units from the same power supply and turn them ON and OFF at the same time. 2. ZEN-8E1AR Expansion I/O Units with AC inputs cannot be connected to CPU Units with DC power supply.
  • Page 15 For CPU Units with 20 I/O points, outputs Q0 to Q3 in the transistor output circuits have independent circuits and outputs Q4 to Q7 have 2 points per common.
  • Page 16 Battery Unit.) Note: 1. With Communications-type CPU Units, the Q3 terminal is used as the RS-485 terminal. For details, refer to “Output Connections” on page 2. Economy-type CPU Units are not provided with an Expansion Unit connector. Do not remove the cover.
  • Page 17 • Changes to connection line write mode. ESC Button OK Button • Inserts a line. Moves the cursor • Moves the cursor up and down. • Moves the cursor up B5 ON up and down. and down. • Selects bit types and functions.
  • Page 18 Phillips screwdriver Flat-blade screwdriver When removing the Expansion Unit connector cover from the side of the CPU Unit, use a Phillips screwdriver to remove the cover screw, and then insert a flat-blade screw driver in the cover gap to remove the cover, as shown at the right.
  • Page 19 Note: 1. For details, refer to the indicated item numbers on the following pages. 2. CPU Units with 10 I/O points have 6 input bits (I0 to I5) and 4 output bits (Q0 to Q3). Output bit Q3 of Communications-type CPU Units, however, cannot be output externally.
  • Page 20 Timer bit When delayed operation or a time lag is required. ■: OFF-delay timer Stays ON while the trigger input is ON and turns OFF after a set delay after the trigger input has turned OFF. Trigger input Basic Operation...
  • Page 21 Counting Speed of the 8-digit Counter The maximum counting speed of the 8-digit counter is 150 Hz. When the ladder program volume is large, however, this speed will be less than 150 Hz. Calculate the cycle time and confirm the maximum counting speed using the following formula. The calculation serves as a guide only, so allow a suitable margin in the actual machine.
  • Page 22 Example Calculation of Ladder Program Execution Time Ladder program execution time = (30 × 5) + (4 × 3) + 15 + 4 + 7 = 188 (µs) *5: P0 *4: @0 *3: T0 (output) *2: Q (outputs) for 3 points...
  • Page 23 2. When L2 or L3 are selected, the ZEN switches to the display function screen if the display function is enabled and the specified data is displayed. The Main Screen will no longer be displayed. To display the Main Screen, change the CPU Unit to STOP mode.
  • Page 24 Communications-type CPU Units) The ZEN has a password function to prevent incorrect manipulation of ladder programs or settings data by other operators. When the password (0000 to 9999) is set, the following operations will not be possible unless the password is input correctly.
  • Page 25 ZEN using a Connecting Cable (ZEN-CIF01). Note: Both RS-485 communications and the ZEN monitoring function cannot be used at the same time with Communications-type CPU Units. The Support Software can also be used to save files and edit comments.
  • Page 26 Dimensions Note: All units are in millimeters unless otherwise indicated. ■ CPU Units CPU Units with 10 I/O Points Unit Mounting Holes ZEN-10C@@@-@-V2 Note: Use M4 screws for mounting. Mounting Hole Dimensions Two, M4 (Sliding: 13 max.) CPU Units with 20 I/O Points ZEN-20C@@@-@-V2 122.5...
  • Page 27 ■ Expansion I/O Units DIN Track Hook (Using Slide) ZEN-8E1@@ Mounting Hole Dimensions Two, 3.5 dia. Two, M3 17.5 ■ Power Supply Unit ZEN-PA03024 Mounting Hole Dimensions Two, M4 (Sliding: 13 max.) ■ Accessories (Order Separately) Battery Unit Memory Cassette...
  • Page 28 • The accuracy of analog inputs has been increased to ± 1.5% FS. • The timing accuracy of weekly timers and calendar timers has been increased to ± 15 s or less per month (at 25 ° C). • Australia and New Zealand Daylight Saving Time (DST) settings have been added.
  • Page 29 • A ZEN-@C@D@-D-V2 CPU Unit with DC power supply cannot be connected to an Expansion I/O Unit with AC inputs. • When connecting Expansion I/O Units with DC inputs to a CPU Unit with an AC power supply, the burst noise immunity will be 1 kV (IEC 61000- 4-4).
  • Page 30 Note: 1. Units with 20 I/O Points: I0 to I9 2. Units with 20 I/O Points: Ia to Ib 3. Refer to page 32 for details on compatible combinations of CPU Units and Expansion I/O Units. Expansion I/O Units Item...
  • Page 31: Other Functions

    Timer/counter comparator bits 16 points 8-digit counter 1 point 8-digit counter comparator bits G 4 points Note: Output bit Q3 of Communications-type CPU Units cannot be output externally. It can be used as a work bit. ZEN V2 Units Programmable Relay...
  • Page 32 ■ Compatible Combinations of CPU Units and Expansion I/O Units The Expansion I/O Units that can be connected to V2 CPU Units are different from those that can be connected to V1 CPU Units and previous CPU Units. Expansion I/O Units with AC Inputs cannot be connected to V2 CPU Units with DC Power Supplies. Expansion I/O Units cannot be connected to Economy-type CPU Units.
  • Page 33 ■ Memory Cassette and CPU Unit Combinations Be aware of the following restrictions when using a Memory Cassette containing a program that was stored from a CPU Unit with a different version of system software. System software version System software version of CPU Unit used to read the Memory Cassette of CPU Unit used to write Ver.
  • Page 34 ZEN failure or external factors. temperature and humidity. The rated ambient operating temperature is 0 to 55 ° C ( − 25 to 55 ° C for LED-type CPU Units). • If the ZEN discovers an error during self-diagnosis, operation will If the ZEN is used near sources of heat, such as a power supply, be stopped and all outputs will be turned OFF.
  • Page 35: Power Supply

    • Attaching or removing the Memory Cassette • Attaching or removing the Battery Unit • If the power supply is interrupted for two days or more (at 25 ° C), the internal capacitor will discharge and internal bit status and the contents of PV areas will be lost or corrupted and dates and times will be reset.
  • Page 36: Warranty And Application Considerations

    CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE...