NC Unit Error Logs
Group
Name
Intelligent
IORD format
Read/Write
error
IOWR format
error
Flash
Flash mem-
memory
ory error
Code
Cause
8700
One of the following errors
occurred when the IORD instruc-
tion was executed:
The NC Unit's address was out-
side the settable range.
8701
One of the following errors
occurred when the IOWR instruc-
tion was executed:
The NC Unit's address was out-
side the settable range.
The parameters for the origin
search high speed and the origin
search proximity speed were not
sent together.
9300
An attempt was made to save
data to flash memory, but the data
couldn't be saved because of a
problem with the flash memory.
Clearing method
Operation after error
Execute the instruc-
The current data trans-
tion again after correct-
fer will not be exe-
ing the data.
cuted, but other
operating axes will not
be affected.
Execute the data save
The current instruc-
operation again. The
tion will not be exe-
error will be cleared if
cuted.
the data is written nor-
All axes will be decel-
mally. Replace the Unit
erated to a stop.
if the error occurs
again.
(In some cases the
data save operation
can take up to 30 s.)
Section 10-1