Appendix E - System Events

Event Code and
String
Triggers
EAA0-R: Prepoly
While in night mode, the prepoly
Refresh Started
refresh started.
EA0-R: Night Mode
While in night mode the system has
Recirc On
automatically entered a low circulation
mode and attempted to turn on all
enabled conditioning zones.
EA00-R: Disp.
A dispense has occurred of the given
Occurred (Shot #)
shot number.
EBA0-R: Prepoly
While in night mode, the prepoly
Refresh Complete
refresh completed successfully.
EB00-R: Stop Button
The Red stop button was pressed on
Pressed
the Advanced Display Module.
EBR0-R: Night Mode
While in night mode the system has
Recirc Off
automatically stopped the low circula-
tion mode and turned off all condition-
ing zones.
ECA1-R: Red Mate-
The Red materials specific gravity was
rial SG Modified
modified.
ECB2-R: Blue Mate-
The Blue materials specific gravity
rial SG Modified
was modified.
ECC1-R: Cavitation
User has turned ON the Cavitation
Errors On
Error Generation logic (default, and
recommended state for production
use) using the ADM module or Field
Bus interface.
ECC0-R: Cavitation
User has turned OFF the Cavitation
Errors Off
Error Generation logic (NOT
recommended for production use)
using the ADM module or Field Bus
interface. If turned OFF, and an HFR
pump does not completely fill, the
error will NOT be generated and the
ratio of the 2 materials may be correct.
This event will also be generated if set
when the HFR (or NVH) product
powers up.
ECD0-R: Mixer Motor
User has activated function (Pressed
Disabled for Dispense
"
effects on future dispenses.
ECD1-R: Mixer Motor
User has re-enabled the mixer motor
Enabled for Dispense
for dispensing.
ECF0-R: Mixer Air
User has activated function (Pressed
OFF for Dispense
"
effects on future dispenses.
ECF1-R: Mixer Air
User has re-enabled Air Nucleation for
Enabled for Dispense
dispensing.
3A2797ZAA
" key) which may have negative
" key) which may have negative
Event Code and
String
Triggers
ECGX: Dispense
The rate (flow or pressure) or amount
Recipe Altered by
has been altered by the controlling
PLC
CGM/PLC interface when the system
was in shot mode.
ECH0-R: Learn Mode
A learn mode calibration was success-
Executed
fully completed.
EH00-R: Gel Timer
The gel timer expired and the system
Dispense
automatically took the gel shot.
EL00-R: System
The System was powered on.
Powered On
EM00-R: System
The System was powered off.
Powered Off
ENN0-R: Automatic
The system was successfully charac-
Cal. Performed
terized with the Automatic calibration.
ENC1-R: Cal. Point 1
A value for the first point in the three
Weight Entered
point calibration was entered.
ENC2-R: Cal. Point 2
A value for the second point in the
Weight Entered
three point calibration was entered.
ENC4-R: Cal. Point 1
The running average for point one of
Weight Erased
the three point calibration was erased.
ENC5-R: Cal. Point 2
The running average for point two of
Weight Erased
the three point calibration was erased.
END0-R: Ratio Check
A ratio check shot was dispensed
Dispense
from the ratio check calibration
screen.
EQU1-R: Settings
The system settings were successfully
Downloaded
transferred from the ADM to a USB
drive.
EQU3-R: Language
The custom language file was suc-
Downloaded
cessfully transferred from the ADM to
a USB drive.
EQU4-R: Language
The custom language file was suc-
Uploaded
cessfully transferred from the USB
drive to the ADM.
EQU5-R: Logs Down-
The Error/Event and Shot data logs
loaded
were successfully transferred from the
ADM to a USB drive.
ER01-R: Shot Count
A counter from the shot counters
Reset
maintenance page was erased
ER02-R: Seq. Posi-
A counter from the sequence counters
tion Count Reset
maintenance page was erased
ERA1-R: Red Material
The resettable totalizer for the Red
Volume Reset
material volume was reset to zero.
ERB1-R: Blue Mate-
The resettable totalizer for the Blue
rial Volume Reset
material volume was reset to zero.
ERA2-R: Red Material
The resettable totalizer for the Red
Weight Reset
material weight was reset to zero.
ERB2-R: Blue Mate-
The resettable totalizer for the Blue
rial Weight Reset
material weight was reset to zero.
ERA3-R: Red Cycle
The resettable cycle counter for the
Count Reset
Red pump was reset to zero.
Appendix E - System Events
89