System Timing; Cli Command Syntax For 7210 Sas Platforms - Nokia 7210 Configuration Manual

Service access switch 7210 sas-m, t, r6, r12, mxp, sx, s basic system
Hide thumbs Also See for 7210:
Table of Contents

Advertisement

System Management

6.11.5 System Timing

When synchronous Ethernet is enabled, the operator can select an Ethernet port as
a candidate for timing reference. The timing information recovered from this port is
used to time the system.
6.11.5.1
This section describes the CLI command syntax to enable synchronous Ethernet on
specific 7210 SAS platforms.
6.11.5.1.1
The following is a sample CLI configuration for the 7210 SAS-M.
*A:MTU>config>system>sync-if-timing# info detail
----------------------------------------------
----------------------------------------------
*A:MTU>config>system>sync-if-timing#
6.11.5.1.2
The following is a sample CLI configuration for the 7210 SAS-R6 and
7210 SAS-R12.
*A:sasr_dutb>config>system>sync-if-timing# info detail
----------------------------------------------
354

CLI command Syntax for 7210 SAS Platforms

CLI Syntax for the 7210 SAS-M
no ql-selection
ref-order ref1 ref2
ref1
shutdown
no source-port
no ql-override
exit
ref2
shutdown
no source-port
no ql-override
exit
ptp
shutdown
no ql-override
exit
no revert
CLI Syntax for 7210 SAS-R6 and 7210 SAS-R12
no ql-selection
Use subject to Terms available at: www.nokia.com
7210 SAS-M, T, R6, R12, Mxp, Sx, S Basic System
© 2021 Nokia.
Configuration Guide
3HE 17358 AAAB TQZZA

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

7210 sas-mxp7210 r67210 r127210 s7210 sx7210 t

Table of Contents