Ptp Ordinary Slave Clock For Frequency - Nokia 7210 Configuration Manual

Service access switch 7210 sas-m, t, r6, r12, mxp, sx, s basic system
Hide thumbs Also See for 7210:
Table of Contents

Advertisement

System Management
Table 38
Note:
State and statistics data for each master clock are available to assist in the detection
of failures or unusual situations.
6.5.8.6
Traditionally, only clock frequency is required to ensure smooth transmission in a
synchronous network. The PTP ordinary clock with slave capability on the 7210 SAS
provides another option to reference a Stratum-1 traceable clock across a packet
switched network. The recovered clock can be referenced by the internal SSU and
distributed to all slots and ports.
Figure 30
Figure 30
296
Support Message Rates for Slave and Master Clock States
Support
Slave Clock
Message
Request Rate
Delay_Resp
User-configurable
with an option to
configure 8/16/32/64
packets/second
Duration
300 seconds
1. Maximum PPS depends on the profile in use

PTP Ordinary Slave Clock for Frequency

shows a PTP ordinary slave clock network configuration.
Slave Clock
1588v2
Grand
Master
1588v2
Grand
Master
Use subject to Terms available at: www.nokia.com
7210 SAS-M, T, R6, R12, Mxp, Sx, S Basic System
Master Clock
Grant Rate
Min
8 packets/second
1 second
Packet
Network
© 2021 Nokia.
Configuration Guide
Max
16 or 64 packets/
1
second
1000 seconds
PTP Slave
OSSG737
3HE 17358 AAAB TQZZA

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

7210 sas-mxp7210 r67210 r127210 s7210 sx7210 t

Table of Contents