15. MR-E- AG-QW003 SERVO AMPLIFIER COMPATIBLE WITH ANALOG INPUT

15.4.2 Details list

Class No. Symbol
0
www.DataSheet4U.com
1
*STY
Control mode, regenerative option selection
Used to select the control mode and regenerative option.
Select the control mode.
0: Speed
1: Speed and torque
2: Torque
Motor series selection
0: HF-KE
1: HF-SE
Selection of regenerative option
0: Regenerative option is not used
2: MR-RB032
3: MR-RB12
4: MR-RB32
5: MR-RB30
6: MR-RB50 (Cooling fan is required)
Motor capacity selection
0: 100W
1: 200W
2: 400W
3: 500W
4: 750W
5: 1kW
6: 1.5kW
7: 2kW
POINT
Wrong setting may cause the regenerative option to burn.
If the regenerative option selected is not for use with the servo
amplifier, parameter error (AL.37) occurs.
*OP1
Function selection 1
Used to select the input signal filter, the function of pin CN1-12.
0
0
CN1-12 function selection
0: Zero Speed detection signal
1: Electromagnetic brake interlock (MBR)
Name and function
W1-S100
JW1-S100
For the servo amplifier of 200W or lower,
regenerative resistor is not used.
For the servo amplifier of 400W or higher,
built-in regenerative resistor is used.
Input signal filter
If external input signal causes chattering
due to noise, etc., input filter is used to
suppress it.
0: None
1: 1.777[ms]
2: 3.555[ms]
3: 5.333[ms]
15 - 35
Initial
Setting
Control
Unit
value
range
mode
100W
Refer to
S T
: 0000
name
and
200W
function
: 1000
column.
400W
: 2000
700W
: 4000
1kW
: 5010
2kW
: 6010
0002
Refer to
S T
name
and
function
column.

Hide quick links: