Parameters - Mitsubishi Electric EZMOTION MR-E Super MR-E-10A-QW003 Instruction Manual

General-purpose ac servo
Table of Contents

Advertisement

8. SPECIAL ADJUSTMENT FUNCTIONS

8.5.3 Parameters

When using the gain changing function, always set "
manual mode of the gain adjustment modes. The gain changing function cannot be used in the auto tuning
mode.
Parameter
Abbrevi
No.
6
36
34
www.DataSheet4U.com
35
37
38
61
GD2B
62
PG2B
63
VG2B
64
VICB
65
66
67
Name
ation
PG1
Position control gain 1
VG1
Speed control gain 1
Ratio of load inertia moment to
GD2
servo motor inertia moment
PG2
Position control gain 2
VG2
Speed control gain 2
VIC
Speed integral compensation
Ratio of load inertia moment to
servo motor inertia moment 2
Position control gain 2 changing
ratio
Speed control gain 2 changing
ratio
Speed integral compensation
changing ratio
CDP
Gain changing selection
CDS
Gain changing condition
CDT
Gain changing time constant
4 " in parameter No.2 (auto tuning) to choose the
Unit
rad/s
Position and speed gains of a model used to set the response
level to a command. Always valid.
rad/s
Multiplier
Control parameters before changing.
1
( 10
)
rad/s
rad/s
ms
Multiplier
Used to set the ratio of load inertia moment to servo motor inertia
1
( 10
)
moment after changing.
Used to set the ratio ( ) of the after-changing position control
gain 2 to position control gain 2.
Used to set the ratio ( ) of the after-changing speed control gain
2 to speed control gain 2.
Used to set the ratio ( ) of the after-changing speed integral
compensation to speed integral compensation.
Used to select the changing condition.
kpps
Used to set the changing condition values.
pulse
r/min
ms
You can set the filter time constant for a gain change at changing.
8 - 6
Description

Hide quick links:

Advertisement