6. DISPLAY AND OPERATION

6.8.4 Motor-less operation

Without connecting the servo motor, you can provide output signals or monitor the status display as if the servo
motor is running in response to external input signals. This operation can be used to check the sequence of a
host programmable controller or the like.
(1) Operation
After turning off the signal across SON-VIN, choose motor-less operation. After that, perform external
operation as in ordinary operation.
(2) Status display
You can confirm the servo status during motor-less operation.
www.DataSheet4U.com
Pressing the "MODE" button in the motor-less operation-ready status calls the status display screen.
With this screen being shown, perform motor-less operation. Every time you press the "MODE" button, the
next status display screen appears, and on completion of a screen cycle, pressing that button returns to the
motor-less operation-ready status screen. For full information of the status display, refer to section 6.2. In
the test operation mode, you cannot use the "UP" and "DOWN" buttons to change the status display screen
from one to another.
(3) Termination of motor-less operation
To terminate the motor-less operation, switch power off.