6. DISPLAY AND OPERATION

6.2.2 Status display list

The following table lists the servo statuses that may be shown.
Name
Cumulative feedback
pulses
Servo motor speed
www.DataSheet4U.com
Droop pulses
Cumulative command
pulses
Command pulse
frequency
Regenerative load ratio
Effective load ratio
Peak load ratio
Instantaneous torque
Within one-revolution
position low
Symbol
Unit
C
pulse
Feedback pulses from the servo motor encoder are counted and displayed.
The value in excess of
display is five digits, it shows the lower five digits of the actual value. Press
the "SET" button to reset the display value to zero.
Reverse rotation is indicated by the lit decimal points in the upper four
digits.
r
r/min
The servo motor speed is displayed.
The value rounded off is displayed in
E
pulse
The number of droop pulses in the deviation counter is displayed. When
the servo motor is rotating in the reverse direction, the decimal points in the
upper four digits are lit.
Since the servo amplifier display is five digits, it shows the lower five digits
of the actual value.
The number of pulses displayed is not yet multiplied by the electronic gear.
P
pulse
The position command input pulses are counted and displayed.
As the value displayed is not yet multiplied by the electronic gear
(CMX/CDV), it may not match the indication of the cumulative feedback
pulses.
The value in excess of
display is five digits, it shows the lower five digits of the actual value. Press
the "SET" button to reset the display value to zero. When the servo motor is
rotating in the reverse direction, the decimal points in the upper four digits
are lit.
n
kpps
The frequency of the position command input pulses is displayed.
The value displayed is not multiplied by the electronic gear (CMX/CDV).
L
The ratio of regenerative power to permissible regenerative power is
displayed in
J
The continuous effective load torque is displayed.
The effective value in the past 15 seconds is displayed relative to the rated
torque of 100 .
b
The maximum torque generated during acceleration/deceleration, etc.
The highest value in the past 15 seconds is displayed relative to the rated
torque of 100 .
T
Torque that occurred instantaneously is displayed.
The value of the torque that occurred is displayed in real time relative to the
rate torque of 100 .
Cy1
pulse
Position within one revolution is displayed in encoder pulses.
The value returns to "0" when it exceeds the maximum number of pulses.
The value is incremented in the CCW direction of rotation.
Description
99999 is counted, bus since the servo amplifier
0.1r/min.
99999 is counted, but since the servo amplifier
.
6 - 3
Display
range
99999
to
99999
5400
to
5400
99999
to
99999
99999
to
99999
800
to
800
0
to
100
0
to
300
0
to
400
0
to
400
0
to
99999