Analog Monitor - Mitsubishi Electric EZMOTION MR-E Super MR-E-10A-QW003 Instruction Manual

General-purpose ac servo
Table of Contents

Advertisement

5. PARAMETERS
(2) Conveyor setting example
For rotation in increments of 0.01 per pulse
Machine specifications
Table : 360 /rev
Reduction ratio: n
Servo motor resolution: Pt
CMX
CDV
www.DataSheet4U.com
Hence, set 5 to CMX and 1 to CDV.

5.2.2 Analog monitor

The servo status can be output to two channels in terms of voltage. Using an ammeter enables monitoring the
servo status.
(1) Setting
Change the following digits of parameter No.17.
Parameters No.31 and 32 can be used to set the offset voltages to the analog output voltages. The setting
range is between
Parameter No.
31
32
1/18
10000 [pulses/rev]
Pt
10000
100
0.01
1/18 360
Parameter No.17
0
0
999 and 999mV.
Used to set the offset voltage for the analog monitor 1 (MO1) output.
Used to set the offset voltage for the analog monitor 2 (MO2) output.
Servo motor
10000 [pulse/rev]
Timing belt : 4/64
5
1
20
Analog monitor 1 (MO1) output selection
(Signal output to across MO1-LG)
Analog monitor 2 (MO2) output selection
(Signal output to across MO2-LG)
Description
5 - 25
Table
Setting range [mV]
999 to 999