1-7-4. Notes for Replacing the CR-1006 Board
A six-axis sensor is installed on the CR-1006 board in the unit.
When the CR-1006 board is replaced, activate the Adjust Manual from the Adjust Station, and then
execute "Gyro Check" and "Level adj" according to the Adjust Manual.
1-7-5. Notes for Replacing the LCD Device
Adjustment values for each LCD element are written on the PD-1066 board of this unit.
Therefore, when the LCD or the PD-1066 board is replaced, start the Adjust Manual from the Adjust
Station. Then adjust the LCD according to the Adjust Manual and write adjustment values.
1-7-6. Notes for Replacing the Front Block (Including IMGR and FIX-5000)
Load data from the CD ROM supplied with the front block to PC. Activate the Adjust Manual from the
Adjust Station, and then write the loaded data to the unit using "Imager DRA Data Write" on the ADJUST
tab of the Adjust Manual.
Then adjust the camera according to the Adjust Manual.
27