19. CTL Chase Function
Reference:
RM-3324S Operation Manual, "4-1 CTL Chase Function"
Note
Using the CTL chase function requires an RM-3324S Remote Control Unit.
19-1. Connections
PCM-3324S
PCM-3348
PCM-3324/3324A
(master unit)
RM-3324S or
other remote
control unit
19-2. Setting the Sampling Frequency
For CTL chase operations, the master and slave units must be set to the same
sampling frequency. If not, the indication "ILLG" appears in the RM-3324S
LOCATE TIME display for the slave unit, and CTL chase operation is not possible.
50
CTL Chase Function
WORD SYNC
OUT
Word sync signal
SECTOR
ADDRESS
OUT
Sector address signal
SECTOR
SYNC
OUT
Sector sync signal
(PCM-3324S only)
WORD SYNC
IN
SECTOR
ADDRESS
PCM-3324S
IN
(slave unit)
SECTOR
SYNC
IN
RM-3324S
TAPE
RECORDER