17. Sector-Based Synchronization
If the SLAVE button does not operate
If pressing the SLAVE button produces an indication "ILLG" on the LOCATE
TIME display, it means that the synchronized operation mode cannot be selected.
This occurs in the following cases.
When the tape transport on the master or slave recorder unit is not stopped.
If the sampling frequencies on the master unit and slave unit are different.
If the timer display mode on the master unit or slave unit is not CTL.

17-3. Rewriting the Sync Offset Time

You can rewrite the sync offset time while the PCM recorder's tape transport is
stopped, or is in playback, fast forward, or rewind mode.
During recording, rehearsal, locate, return playback, or auto punch-in/out operations,
it is not possible to rewrite the sync offset time.
Procedure
1
Use the SF.mS/F.S button to set the LOCATE TIME display to the mSEC
mode.
2
Press and light the RECALL button, then press the SYNC OFFSET button to
display the sync offset time on the LOCATE TIME display.
3
Enter the change to the sync offset time using the numeric buttons.
For example, to reduce the value by 55 ms, press the –, 5, 5, and = buttons in
that order. To increase the value, press the + button in place of the – button.
4
Press and light the STORE button, then press the SYNC OFFSET button.
The PCM recorder connected to the RM-3324/3348HR slave unit on which you
changed the sync offset time operates in synchronization with the new sync
offset time.
Adjusting the value with the TRIM +/– buttons
Holding down the SYNC OFFSET button, press the TRIM +/– buttons to adjust the
value.
After adjustment, the new sync offset time is stored.